Summary for Test 2017-05-09-10-2
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 212036 DEA: 044K2404 EFIS: 0417000284 |
---|---|
DIST-CO-RTE-PM | 04-MRN,MRN-1-10.9, 10.8/10.9, 10.90, 6.6/10.9 |
Award Date | 01/31/2017 |
Closeout Date | 10/17/2022 |
Work Description | Construct Solier Pile Wall |
Location Description | Not set |
QA Service Level | 1 (Verified on 03/17/2017) |
Sample Information
Sample Taken Date | 05/09/2017 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2017 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 6x12 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Harry | Last name of sampler or witnessed by | Suryantoro |
Title of sampler | Transportation Engineer | Telephone number of sampler | 1-707-333-4263 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Shamrock | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Retaining Wall |
Material Information
Material Type | Concrete | The concrete mix design number | 4700P |
---|---|---|---|
The truck number from where the sample was collected | 1808 | The batch plant ticket number from where the sample was collected | 153921 |
Concrete batch plant | 1 | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Mix Truck Chute | Where the material sample would have been placed if not sampled | soldier pile wall |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2017-05-09-10
DIME Test ID: 2017-05-09-10-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-06-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 06/06/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 184208 lb
Maximum load on cylinder 2: 201021 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 6493.1 psi
Compressive strength of cylinder 2: 7085.7 psi
Compressive strength (to nearest 10 psi): 6790 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 6/6/2017 ✔