Summary for Test 2024-04-09-21-2
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 994733 DEA: 043Q5704 EFIS: 0419000225 |
---|---|
DIST-CO-RTE-PM | 04-SF, -101,280-VAR |
Award Date | 06/20/2023 |
Closeout Date | Not set |
Work Description | STRENGTHEN GIRDER, CLEAN AND PAINT STRUCTURAL STEEL, & REPAIR DECK. |
Location Description | THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
Sample Taken Date | 04/09/2024 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/11/2024 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A563 Nuts |
The quantity of what the sample constitutes | 701 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jamie | Last name of sampler or witnessed by | Doe |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | (916) 838-4405 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | C&K Johnson Ind. | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-016-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 415163501 415163502 415163503 415163504 415163505 415163506 |
---|---|---|---|
Heat Number(s) | 8000015558 | Nut Mfg. Lot Number(s) | W000011953 |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM A325 | |
Bolt Length(s) | Nut Specification | ASTM A563 | |
Washer Specification | ASTM F436 | Finish | ASTM A153/F2329 |
Diameter/Size | 7/8-9 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2024-04-09-21
DIME Test ID: 2024-04-09-21-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-04-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 04/17/2024
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | 75178 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 4/19/2024 ✔