Summary for Test 2024-03-20-8-2
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/20/2024 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/28/2024 |
Sample type | Quality Assurance | A brief description of the sample | Carriage Bolt |
The quantity of what the sample constitutes | 1520 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 385-452-2398 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc. | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-036-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
---|---|---|---|
Heat Number(s) | 20844580 | Nut Mfg. Lot Number(s) | na |
Washer Mfg. Lot Number(s) | na | Bolt Specification | A325 S |
Bolt Length(s) | 7" | Nut Specification | na |
Washer Specification | na | Finish | HDG |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 61570 |
Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
Test Details
DIME Sample ID: 2024-03-20-8
DIME Test ID: 2024-03-20-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2024-04-08
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 04/08/2024
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | 61570 | 0.5000 | 20258 | 90.11 | 10.00 | Wedge Tensile | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 4/8/2024 ✔