Summary for Test 2024-03-06-8-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 994728 DEA: 032J8104 EFIS: 0322000102 |
---|---|
DIST-CO-RTE-PM | 03-BUT-99-R30.6,R31.5 |
Award Date | 07/17/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT SLOPE PAVING AND INSTALL AESTHETIC FEATURE. |
Location Description | BUTTE COUNTY IN CHICO AT SKYWAY OVERCROSSING AND AT EAST 20TH STREET OVERCROSSING |
QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
Sample Taken Date | 03/06/2024 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/07/2024 |
Sample type | Quality Assurance | A brief description of the sample | PCC |
The quantity of what the sample constitutes | Pour Location | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Baker |
Title of sampler | Telephone number of sampler | 5306055863 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Mathews Readymix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 07035P15 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 17027390 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Discharge from BACK OF concrete truck CHUTE into wheelbarrow. | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-03-06-8
DIME Test ID: 2024-03-06-8-1
Testing Lab: CT D03 - Chico Field Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-04-03
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brad McKeehan
Date of test: 04/03/2024
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 74150 lb
Maximum load on cylinder 2: 74620 lb
Maximum load on cylinder 3: 73180 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5899.0 psi
Compressive strength of cylinder 2: 5936.4 psi
Compressive strength of cylinder 3: 5821.8 psi
Compressive strength (to nearest 10 psi): 5890 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2024 ✔