Summary for Test 2024-03-22-5-2
Test performed: ASTM D412-16r21Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/22/2024 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2024 |
Sample type | Quality Assurance | A brief description of the sample | Elastomeric joint seal |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Watson Bowman Acme Corp | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0124157 |
---|---|---|---|
Manufacturer(s) | Watson Bowman Acme Corp | Temperature | 72 |
Humidity | 50 | Comments | |
Joint Seal Size | 1.75 |
Test Details
DIME Sample ID: 2024-03-22-5
DIME Test ID: 2024-03-22-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2024-04-11
Test Results
Number of specimens tested: 5
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/03/2024
UTM: 2KIP
Humidity: 72 %
Temperature: 50 f
Sample 1 Median Thickness: 0.08 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2188.31 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.081 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 1825.56 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.078 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2198.85 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Sample 4 Median Thickness: 0.075 in
Sample 4 Thickness all Within 0.003 inch?: Yes
Sample 4 Ultimate Tensile: 2001.91 lbf/in^2
Sample 4 Elongation (350% Min): Pass
Sample 5 Median Thickness: 0.075 in
Sample 5 Thickness all Within 0.003 inch?: Yes
Sample 5 Ultimate Tensile: 1976.18 lbf/in^2
Sample 5 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2001.9 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/11/2024 ✔