Summary for Test 2017-05-24-6-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212164
DEA: 051J1304
EFIS: 0517000064
DIST-CO-RTE-PM05-MON,MON-1-45.52, 45.4/45.8
Award Date02/16/2017
Closeout Date10/25/2019
Work DescriptionPfeiffer Canyon Emergency Bridge Replacement Project
Location DescriptionHighway 1 at Pfeiffer State Park
QA Service Level1 (Verified on 02/27/2017)

Sample Information

Sample Taken Date05/24/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/31/2017
Sample typeQuality Assurance A brief description of the sampleA325 HDG Rocap Assembiy
The quantity of what the sample constitutes141 From where was the sample collectedManufacturer
First name of sampler or witnessed byJeff Last name of sampler or witnessed bySmith
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSt Louis Screw Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB0737417 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0085221 TT0085224 TT0085225 TT0085226 TT0085203 TT0085228 TT0085229 TT0085230 TT0085231 TT0085232 TT0085233 TT0085234 TT0085236
Heat Number(s) Nut Mfg. Lot Number(s)25305-166976 23840-75063408
Washer Mfg. Lot Number(s)D3402 D3289 Bolt SpecificationA325
Bolt Length(s)3.25" 4.25" 4.75" 5.5" 6" 7.5" 8.75" 1 Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1" 0.875" Bolt Mfg. Lot NumberBG0861 BG0753 BG0697 BG0565 041972/G8842
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-05-24-6
DIME Test ID: 2017-05-24-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-06-08

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/01/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BB07374171\"88964395.710A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 6/1/2017