Summary for Test 2024-03-05-31-5
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 994869 DEA: 073237U4 EFIS: 0720000224 |
---|---|
DIST-CO-RTE-PM | 07-VEN-150-13.3/19 |
Award Date | 03/27/2023 |
Closeout Date | Not set |
Work Description | PLACE HMA (TYPE A) AND COLD PLANE ASPHALT |
Location Description | VENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD |
QA Service Level | 1 (Verified on 06/26/2023) |
Sample Information
Sample Taken Date | 03/05/2024 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2024 |
Sample type | Verification | A brief description of the sample | JMF 3/4" HMA-A-SP R30 4.8% Rejuvenato |
The quantity of what the sample constitutes | 4 Bags of Comb. Aggregate, 1 Bag Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | K |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0134A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials- Saticoy | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0020,91-19-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Belt Cut at Vulcan Materials- Saticoy | |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | 220203E SAT LTR | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-03-05-31
DIME Test ID: 2024-03-05-31-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-05-14
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Robert Guillen
Date of test: 03/17/2024
Clay Level (Test 1): 5.7
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.8
Sand Level (Test 2): 4.1
Clay Level (Test 3): 5.9
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 69
Sand Equivalent (Test 2): 71
Sand Equivalent (Test 3): 68
Sand Equivalent: 70
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/14/2024 ✔