Summary for Test 2024-03-05-30-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994869
DEA: 073237U4
EFIS: 0720000224
DIST-CO-RTE-PM07-VEN-150-13.3/19
Award Date03/27/2023
Closeout DateNot set
Work DescriptionPLACE HMA (TYPE A) AND COLD PLANE ASPHALT
Location DescriptionVENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD
QA Service Level1 (Verified on 06/26/2023)

Sample Information

Sample Taken Date03/05/2024 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/12/2024
Sample typeVerification A brief description of the sampleJMF-3/4" HMA-A-SP R 0 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Combined Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byAvo Last name of sampler or witnessed byKarajian
Title of sampler Telephone number of sampler
Laboratory sample identification0133A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials- Saticoy Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035 - 91-19-0020
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials- Saticoy
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number220817 SAT LTR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-03-05-30
DIME Test ID: 2024-03-05-30-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-05-14

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Satish Jain/M. Campos
Date of test: 03/17/2024
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 88 %
Cumulative percent passing the 3/8 in. sieve: 74 %
Cumulative percent passing the #4 sieve: 48 %
Cumulative percent passing the #8 sieve: 36 %
Cumulative percent passing the #16 sieve: 26 %
Cumulative percent passing the #30 sieve: 18 %
Cumulative percent passing the #50 sieve: 12 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4.6 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 5/14/2024