Summary for Test 2024-02-06-15-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 1000130 DEA: 021J3504 EFIS: 0220000061 |
---|---|
DIST-CO-RTE-PM | 02-SHA-29-41.1/55.3 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Diddy Roost Culverts - Drainage System Restoration |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/24/2024) |
Sample Information
Sample Taken Date | 02/06/2024 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2024 |
Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation, C-3 |
The quantity of what the sample constitutes | 1 container for culvert recommendation | From where was the sample collected | Source |
First name of sampler or witnessed by | Terry | Last name of sampler or witnessed by | Schmitt |
Title of sampler | MREAS | Telephone number of sampler | |
Laboratory sample identification | D79400 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 897803 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SHA-299-50.3, 0.5' ft. streambed inlet | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-02-06-15
DIME Test ID: 2024-02-06-15-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-05-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 02/12/2024
Minimum soil resistance of the lab measurement: 14000 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 7.53
Minimum soil resistance corrected to 15.5: 16240 Ohm-cm
Minimum soil resistivity at 15.5: 16240 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=7.08, p=5499.Ω∙cm
Test was verified on 5/20/2024 ✔