Summary for Test 2013-03-26-14187147-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 03/26/2013 | Sample Unique Key | 14187147 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Control | A brief description of the sample | concrete |
The quantity of what the sample constitutes | 4 cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | brett | Last name of sampler or witnessed by | soldano |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | vulcan materials | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Concrete | The concrete mix design number | 234524df |
---|---|---|---|
The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 23 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | wheelbarrow | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2013-03-26-14187147
DIME Test ID: 2013-03-26-14187147-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2013-03-26
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed:
Input Type: Calculated
Tester's full name: jim devey
Date of test: 03/26/2013
Comment on any defect in either specimen or caps (Max 250 Characters): no data
General comments (publicly viewable) (Max 1000 characters): test
Test was verified on 3/26/2013 ✔