Summary for Test 2017-04-26-4-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 210696
DEA: 080M2804
EFIS: 0800000472
DIST-CO-RTE-PM08-SBD-15-171.8/173.8
Award Date11/04/2015
Closeout Date08/21/2018
Work DescriptionBRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location DescriptionIn SBD County
QA Service Level1 (Verified on 10/19/2015)

Sample Information

Sample Taken Date04/26/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2017
Sample typeQuality Assurance A brief description of the sample Coupon Castings
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDSI, Dotson Iron Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)1097, 1117
Part Number (s)68 19 216 248 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Dotson Iron Castings
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2017-04-26-4
DIME Test ID: 2017-04-26-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-05-11

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 05/01/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
110970.4970.194477778383012Fred
211170.4970.194464287598016.6Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 5/4/2017