Summary for Test 2017-04-20-3-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 7428 DEA: 07215944 EFIS: 0700001834 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-4.0/5.9 |
Award Date | 08/23/2012 |
Closeout Date | 07/02/2021 |
Work Description | RECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES. |
Location Description | LOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/07/2012) |
Sample Information
Sample Taken Date | 04/20/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2017 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Gray |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | C720056 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S3201517 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 137915 |
Hoop Manufacturer Lot Number(s) | 7 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 8 |
Diameter of Hoop | 6'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | RKR Steel |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-20-3
DIME Test ID: 2017-04-20-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-05-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/25/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 7 | #8/25mm | 0.79 | 76090 | 96320 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/26/2017 ✔