Summary for Test 2017-04-21-2-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 211513 DEA: 120M4904 EFIS: 1212000090 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-1.2/2.2 |
Award Date | 09/20/2016 |
Closeout Date | 01/09/2020 |
Work Description | WIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS. |
Location Description | ORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING |
QA Service Level | 1 (Verified on 11/03/2016) |
Sample Information
Sample Taken Date | 04/21/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2017 |
Sample type | Quality Assurance | A brief description of the sample | Headed Bars |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | Mclaurin |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC HRC | Transportation Laboratory (TL) Number | C943834 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L6708417 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Retest |
---|---|---|---|
Rebar Heat Number(s) | 4061558 | Head Manufacturer Lot Number(s) | 1 |
Rebar Size | 9 | Headed Bar Model Name | HRC 120 |
Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | CMC |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-04-21-2
DIME Test ID: 2017-04-21-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-05-02
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/24/2017
UTM: 2000KIP
Temperature: 71 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1 | 97500 | 97500 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/25/2017 ✔