Summary for Test 2017-04-17-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212164
DEA: 051J1304
EFIS: 0517000064
DIST-CO-RTE-PM05-MON,MON-1-45.52, 45.4/45.8
Award Date02/16/2017
Closeout Date10/25/2019
Work DescriptionPfeiffer Canyon Emergency Bridge Replacement Project
Location DescriptionHighway 1 at Pfeiffer State Park
QA Service Level1 (Verified on 02/27/2017)

Sample Information

Sample Taken Date04/17/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC739977
Inspector Lot Number from the Transportation Laboratory (TL) FormB1016017 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)580967
Hoop Manufacturer Lot Number(s)H04, H05 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Rebar
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-04-17-1
DIME Test ID: 2017-04-17-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13H04#6/19mm0.444395699900necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/18/2017