Summary for Test 2023-11-17-48-1
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/17/2023 | Sample Unique Key | 48 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/17/2023 |
Sample type | Quality Control | A brief description of the sample | PG64-10 |
The quantity of what the sample constitutes | 1 of 2 cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Conner |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 6410231117 | Linked DIME Sample ID | 2023-11-17 |
The fabricator/manufacturer/facility name | San Joaquin Refining Co Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | No | Lot number | 6410231117 |
Sublot number | Tank number | 20004 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-11-17-48
DIME Test ID: 2023-11-17-48-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2023-11-29
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: Sandra Ponce
Date of test: 11/17/2023
Observed Flash Point: 590 F
Ambient Barometric Pressure: 755 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 590 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/29/2023 ✔