Summary for Test 2023-11-17-48-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/17/2023 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/17/2023
Sample typeQuality Control A brief description of the samplePG64-10
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byConner
Title of sampler Telephone number of sampler
Laboratory sample identification6410231117 Linked DIME Sample ID2023-11-17
The fabricator/manufacturer/facility nameSan Joaquin Refining Co Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number6410231117
Sublot number Tank number20004
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-11-17-48
DIME Test ID: 2023-11-17-48-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2023-11-29

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: Sandra Ponce
Date of test: 11/17/2023
Observed Flash Point: 590 F
Ambient Barometric Pressure: 755 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 590 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/29/2023