Summary for Test 2017-03-06-7-4

Test performed: ASTM C109-11

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/06/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2017
Sample typeProficiency A brief description of the sampleCCRL 079
The quantity of what the sample constitutes7800 Grams From where was the sample collectedOther
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationCM178079 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCCRL Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2017-03-06-7
DIME Test ID: 2017-03-06-7-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2019-02-19

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: SD
Date of test: 04/11/2017
Age of specimen: 27 days
The amount of flow (In percent): 115 %
The amount of water used (In percent): 46 %
Maximum load of 1st specimen (lb): 20965 lbf
Maximum load of 2nd specimen (lb): 22497 lbf
Maximum load of 3rd specimen (lb): 20800 lbf
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Compressive strength of 1st specimen (psi): 5241 psi
Compressive strength of 2nd specimen (psi): 5624 psi
Compressive strength of 3rd specimen (psi): 5200 psi
Average Compressive strength (to nearest 10 psi): 5360 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break
Test Graph
Source: Partner Data Point File
Test graph for Specimen 1 of 3

Source: Partner Data Point File
Test graph for Specimen 2 of 3

Source: Partner Data Point File
Test graph for Specimen 3 of 3

Test was verified on 2/12/2019