Summary for Test 2023-11-20-5-1
Test performed: ASTM A970-18Project Information
Project Identifiers | Project ID: 993253 DEA: 033F0604 EFIS: 0312000052 |
---|---|
DIST-CO-RTE-PM | 03-GLE-162-76.3/78.6 |
Award Date | 02/02/2022 |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 11/20/2023 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/21/2023 |
Sample type | Quality Assurance | A brief description of the sample | #6 555 Headed Bar Lot 40 |
The quantity of what the sample constitutes | 150 HRC 555 Heads | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Haynes |
Title of sampler | QA Inspector | Telephone number of sampler | (510) 593-1179 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar Fresno, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S81-062-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4134020 | Head Manufacturer Lot Number(s) | NA |
Rebar Size | #6 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | CMC Steel Arizona |
Head Manufacturer | HRC | Head Fabricator | CMC Rebar Fresno |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | 4FG-17-01 |
Test Details
DIME Sample ID: 2023-11-20-5
DIME Test ID: 2023-11-20-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-11-28
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 11/22/2023
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 40 | 0.44 | 43096 | 97945 | Ok Necking | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/28/2023 ✔