Summary for Test 2017-04-03-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210696
DEA: 080M2804
EFIS: 0800000472
DIST-CO-RTE-PM08-SBD-15-171.8/173.8
Award Date11/04/2015
Closeout Date08/21/2018
Work DescriptionBRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location DescriptionIn SBD County
QA Service Level1 (Verified on 10/19/2015)

Sample Information

Sample Taken Date04/03/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/05/2017
Sample typeQuality Assurance A brief description of the sampleDayton Bar lock couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byFaisal Last name of sampler or witnessed byZahlout
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Dayton Superior Transportation Laboratory (TL) NumberC018
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#5 Coupler ModelBar Lock Stanard Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A150277, A143804 Rebar Heat Number(s)6502646702
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-04-03-1
DIME Test ID: 2017-04-03-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-04-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/06/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13BL5-1#5/6mm0.3103091699729Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/6/2017