Summary for Test 2017-03-28-2-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210041 DEA: 043G4864 EFIS: 0412000086 |
---|---|
DIST-CO-RTE-PM | 04-SM-92-14.4/18.8 |
Award Date | 12/18/2015 |
Closeout Date | 08/22/2018 |
Work Description | CLEAN AND PAINT STRUCTURAL STEEL ON BRIDGE |
Location Description | IN SAN MATEO AND ALAMEDA COUNTIES ON ROUTE 92 AT SAN MATEO HAYWARD |
QA Service Level | 1 (Verified on 11/05/2014) |
Sample Information
Sample Taken Date | 03/28/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/30/2017 |
Sample type | Quality Assurance | A brief description of the sample | 1-8 x 3 3/4 Heavy Hex bolt |
The quantity of what the sample constitutes | 1875 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacific Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-018-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412022 |
---|---|---|---|
Heat Number(s) | 10449580 166642 11606780 | Nut Mfg. Lot Number(s) | 24618-166642Z |
Washer Mfg. Lot Number(s) | D2553 | Bolt Specification | A325 |
Bolt Length(s) | 3-3/4" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | Mech Galv |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 773920 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-03-28-2
DIME Test ID: 2017-03-28-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-04-11
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/03/2017
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | B36201817 | 1\" | 93321 | 415.1 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 4/4/2017 ✔