Summary for Test 2017-02-14-7-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 212300 DEA: 044G3804 EFIS: 0412000463 |
---|---|
DIST-CO-RTE-PM | 04-SON-116-30.9/31.4 |
Award Date | 03/15/2019 |
Closeout Date | 02/16/2024 |
Work Description | Construct Bridge, Retaining Walls, Traffic Signal |
Location Description | SONOMA COUNTY NEAR COTATI FROM 0.3 MILE EAST OF HESSEL ROAD TO 0.1 MILE EAST OF BARTLESON ROAD |
QA Service Level | 1 (Verified on 08/19/2019) |
Sample Information
Sample Taken Date | 02/14/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2017 |
Sample type | Quality Control | A brief description of the sample | BRIDGE |
The quantity of what the sample constitutes | 1 BAG | From where was the sample collected | Job Site |
First name of sampler or witnessed by | MENG HSI | Last name of sampler or witnessed by | HUNG |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0060 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C232356 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-17-005 |
Where the material sample would have been placed if not sampled | 7 TO 10 FT |
Test Details
DIME Sample ID: 2017-02-14-7
DIME Test ID: 2017-02-14-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-04-10
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 04/03/2017
Total mass of material in the sample: 3464 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 0 grams
Cumulative mass retained on the 3/8 in. sieve: 7 grams
Cumulative mass retained on the #4 sieve: 16 grams
Cumulative mass retained on the #8 sieve: 8 grams
Total sample mass passing the #4 sieve: 945 grams
Total mass of fine material in the sample: 470 grams
Cumulative mass retained on the pan: 463 grams
Total cumulative mass of coarse aggregate: 23 grams
Total cumulative mass of fine aggregate: 471 grams
Sum of coarse and fine aggregate: 968 grams
Percentage of coarse material: 2 %
Percentage of fine material: 98 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 99 %
Cumulative percent passing the #4 sieve: 98 %
Cumulative percent passing the #8 sieve: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2017 ✔