Summary for Test 2017-03-23-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211226
DEA: 024E6404
EFIS: 0212000011
DIST-CO-RTE-PM02-PLU-147-8.9/9.3
Award Date05/10/2016
Closeout Date11/12/2020
Work DescriptionREPLACE BRIDGE, GUARDRAILING, HMA, STRIPING
Location DescriptionPLUMAS COUNTY ABOUT 9 MILES NORTH OF CANYON DAM FROM 0.1 MILE SOUTH TO 0.4 MILE NORTH OF HAMILTON BRANCH BRIDGE
QA Service Level1 (Verified on 04/21/2016)

Sample Information

Sample Taken Date03/23/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/27/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byG Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC953696
Inspector Lot Number from the Transportation Laboratory (TL) FormL5306417 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)6502634303
Hoop Manufacturer Lot Number(s)1, 5, 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-03-23-7
DIME Test ID: 2017-03-23-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-05

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/28/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#6/19mm0.444134093950Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/29/2017