Summary for Test 2017-03-06-7-11
Test performed: ASTM C430-8Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/06/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/06/2017 |
Sample type | Proficiency | A brief description of the sample | CCRL 079 |
The quantity of what the sample constitutes | 7800 Grams | From where was the sample collected | Other |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM178079 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CCRL | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | CCRL |
---|---|---|---|
Mill | CCRL | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2017-03-06-7
DIME Test ID: 2017-03-06-7-11
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2019-02-19
Test Results
Type of Material: Hydraulic Cement
Input Type: Calculated
Tester's full name: Stephen Donnelly
Date of test: 03/22/2017
Residue from the sample retained on the No. 325 sieve (Rs): 0.0021 grams
Sieve correction factor (C): 33.89
Corrected residue, % (Rc): 0.28 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 99.72 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/12/2019 ✔