Summary for Test 2017-01-10-7-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 01/10/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2017 |
Sample type | Quality Assurance | A brief description of the sample | .62in Prestressing Strand |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Insteel Wire | Transportation Laboratory (TL) Number | C939308 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0800317 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | Unknown | Strand Diameter | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | NA | Mfg. Lot Number(s) | 120340771591, 120340771593, 120340771596, |
Manufacturer(s) | Insteel Wire Products |
Test Details
DIME Sample ID: 2017-01-10-7
DIME Test ID: 2017-01-10-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-03-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/22/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 120340771593 | 0.233 | 64966 | 59260 | 28.5 | 1.87 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/22/2017 ✔