Summary for Test 2023-10-10-49-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 994443 DEA: 053307C4 EFIS: 0514000028 |
---|---|
DIST-CO-RTE-PM | 05-SLO-41,46-44.5/45.3,54.0/57.8 |
Award Date | 02/27/2023 |
Closeout Date | Not set |
Work Description | Wye Segment - Route 41/46 Separation |
Location Description | Not set |
QA Service Level | 1 (Verified on 12/16/2022) |
Sample Information
Sample Taken Date | 10/10/2023 | Sample Unique Key | 49 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2023 |
Sample type | Department Acceptance | A brief description of the sample | 4x8 Concrete Cylinders |
The quantity of what the sample constitutes | Trial Batch - 3F40L003 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Engen |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Holliday Rock | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Trial Batch-Structures |
Material Information
Material Type | Concrete | The concrete mix design number | 3F40L003 |
---|---|---|---|
The truck number from where the sample was collected | 734 | The batch plant ticket number from where the sample was collected | 20100591 |
Concrete batch plant | Holliday Rock Company | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Mix Truck | Where the material sample would have been placed if not sampled | Trial Batch |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-10-10-49
DIME Test ID: 2023-10-10-49-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-10-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 10/13/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 37163 lb
Maximum load on cylinder 2: 35342 lb
Maximum load on cylinder 3: 35070 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 3 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 2,956.5 psi
Compressive strength of cylinder 2: 2,811.6 psi
Compressive strength of cylinder 3: 2,790.0 psi
Compressive strength (to nearest 10 psi): 2850 psi
General comments (publicly viewable) (Max 1000 characters): 3 Day Break for Trial Batch
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
05-3307C4_CTM 521_KEE_231010_3F40L003_Trial Batch_3 Day_3x_1 | 84.33 KB | 10/16/2023 | 2023-10-10-49-1 | Info |
Test was verified on 10/16/2023 ✔