Summary for Test 2017-03-07-1-10

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/07/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/10/2017
Sample typeQuality Assurance A brief description of the sample.6 Strand
The quantity of what the sample constitutes75 From where was the sample collectedSource
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)NA Number of CoilsUnknown
Group NumberUnknown Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0288884 S0288885 S0288890 S0290079 S0290083 S0290084 S0290085-2 S0290087 S0290088 S0514016 S0514316-2 S0522816 S0523016 S0523116 S0534016 S0534716 S0543616 S0544016 S0544116 S0590016 Mfg. Lot Number(s)N/A
Manufacturer(s)Sumiden

Test Details

DIME Sample ID: 2017-03-07-1
DIME Test ID: 2017-03-07-1-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-03-24

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 03/14/2017
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0290083S333996-30.214597455464528.51.86Arnold

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/17/2017