Test 2017-01-09-3-6 (ASTM C191-13) Summary

Project Information
Project IdentifiersProject ID: 88888
DEA: STOCK
EFIS: STOCK
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date1/9/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/9/2017
Sample typeAnnual Source Testing A brief description of the sampleType I/II
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Laboratory sample identificationCM175702
The fabricator/manufacturer/facility nameLaFarge Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeCementitious BrandLaFarge
MillRichmond BC Type of Cementitious MaterialType II Cement
Test Details
DIME Sample ID: 2017-01-09-3
DIME Test ID: 2017-01-09-3-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2018-07-24
Test Results

Input Type: Measured
Tester's full name: timothy omalley
Date of test: 02/15/2017
Type of Water Used: Type III grade reagent water
Time in minutes of last penetration greater than 25mm (E): 90 min
Time in minutes of first penetration less than 25mm (H): 105 min
Penetration reading at time E : 36 mm
Penetration reading at time H: 24 mm
Initial time of setting:104 min
Final time of setting:0 min
Method Used:Test Method A
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/17/2018