Summary for Test 2023-07-10-53-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 995018 DEA: 09392204 EFIS: 0922000038 |
---|---|
DIST-CO-RTE-PM | 09--- |
Award Date | 04/13/2023 |
Closeout Date | 11/08/2023 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 05/17/2023) |
Sample Information
Sample Taken Date | 07/10/2023 | Sample Unique Key | 53 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/31/2023 |
Sample type | Preliminary | A brief description of the sample | Asphalt rubber PSU |
The quantity of what the sample constitutes | 2 cans of binder | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | VSS Emultech West Sac | Transportation Laboratory (TL) Number | C 993502 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 58-22 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2023-07-10-53
DIME Test ID: 2023-07-10-53-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2023-08-14
Test Results
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 08/11/2023
Temperature: 25 C
Final Dial reading (F1): 60 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 57 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F3): 55 mm
Ball Penetration (P3): 1 mm
Resilience 1: 40 %
Resilience 2: 44 %
Resilience 3: 46 %
Average Resilience: 43 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/14/2023 ✔