Summary for Test 2016-12-15-11-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211070
DEA: 080Q3004
EFIS: 0800020191
DIST-CO-RTE-PM08-SBD-138-R17.1/R19.2
Award Date04/18/2016
Closeout Date09/28/2020
Work DescriptionREALIGN SECTION OF STATE ROUTE 138
Location DescriptionNear Hesperia from 1.9 mi East of Route 15 to 0.1 mi West of Summit Post Office Road to realign sections of State Route 138
QA Service Level1 (Verified on 04/27/2016)

Sample Information

Sample Taken Date12/15/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/03/2017
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTim Last name of sampler or witnessed byFlores
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Gerdau Transportation Laboratory (TL) NumberC750001
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#14 Coupler Model500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)58018522, 73091916, 74095974 Rebar Heat Number(s)6502198302
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-12-15-11
DIME Test ID: 2016-12-15-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-01-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/04/2017
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#14/43mm2.25-0.009521288394615necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 1/5/2017