Summary for Test 2023-06-27-42-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 993646 DEA: 080R1414 EFIS: 0815000200 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R100.0/R125.0 |
Award Date | 05/11/2022 |
Closeout Date | 03/27/2024 |
Work Description | ROADWAY EXCAVATION, DESERT TORTOISE FENCE, AND BONDED FIBER MATRIX. |
Location Description | SAN BERNARDINO COUNTY AT AND NEAR FENNER FROM ESSEX ROAD OVERCROSSING TO 4.5 MILES EAST OF WATER ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 06/27/2023 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2023 |
Sample type | Quality Assurance | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 10000SQF | From where was the sample collected | Job Site |
First name of sampler or witnessed by | larry | Last name of sampler or witnessed by | francisco |
Title of sampler | TE | Telephone number of sampler | |
Laboratory sample identification | 06272023TEST 01 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOBSITE | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-06-27-42
DIME Test ID: 2023-06-27-42-1
Testing Lab: CT D08 - Blythe Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-06-28
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: larry francisco
Date of test: 06/27/2023
Gage No.: 33196
Test No.: 1
Nuclear By: larry francisco
Non-Bias Plan No.: 1
Depth: 8
Material No.: NATIVE
Material Type: SUBGRADE
Impact By: LARRY FRANCISCO
Standard Count Density: 1775 g/cc
Count or Density 1: 1533 g/cc
Count or Density 2: 1632 g/cc
Count or Density 3: 1521 g/cc
Count or Density 4: 1670 g/cc
Count or Density 5: 1610 g/cc
Standard Count Moisture: 764 g/cc
Moisture Count 1: 74 g/cc
Moisture Count 2: 80 g/cc
Moisture Count 3: 74 g/cc
Moisture Count 4: 84 g/cc
Moisture Count 5: 71 g/cc
Sum of Count or Density: 7966 g/cc
Average of Count or Density: 1593 g/cc
Sum of Moisture Count: 383 g/cc
Average of Moisture Count: 77 g/cc
Count Ratio Density: 0.9
Count Ratio Moisture: 0.1
Calculated Percent Relative Compaction: 95.4 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/28/2023 ✔