Summary for Test 2023-06-03-8-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994784
DEA: 010M0104
EFIS: 0122000075
DIST-CO-RTE-PM01-DN-197-R0/7.1
Award Date01/31/2023
Closeout Date08/22/2023
Work DescriptionProject Name: Smith River Micro-Surfacing
Location DescriptionNot set
QA Service Level1 (Verified on 05/04/2023)

Sample Information

Sample Taken Date06/03/2023 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/09/2023
Sample typeQuality Control A brief description of the sampleEmulsion
The quantity of what the sample constitutes2 OF 2 From where was the sample collectedJob Site
First name of sampler or witnessed byEric Last name of sampler or witnessed bySisneros
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVSS Emultech Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeMSE
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2023-06-03-8
DIME Test ID: 2023-06-03-8-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-06-08

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Humberto Ramirez
Date of test: 06/08/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 144.1 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 112.5 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 143.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 111.9 g
Beaker 1 Residue: 63.2 %
Beaker 2 Residue: 63.0 %
Percentage of residue: 63 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 6/8/2023