Summary for Test 2023-06-01-39-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R9.7 |
Award Date | 04/03/2020 |
Closeout Date | 06/06/2024 |
Work Description | PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/05/2020) |
Sample Information
Sample Taken Date | 06/01/2023 | Sample Unique Key | 39 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/02/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/8" HMA DIKE 63763-2 |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 23-169 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 0601A2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | |
Sublot number | HMA Mix Number | 637632 SV |
Test Details
DIME Sample ID: 2023-06-01-39
DIME Test ID: 2023-06-01-39-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-06-06
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 06/06/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4025.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5614.0 g
Mass of HMA Sample prior to ignition: 1588.3 g
Mass Loss: 103.0 g
Mass of aggregate remaining after ignition: 1485.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.48 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/6/2023 ✔