Summary for Test 2023-05-22-69-1
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R9.7 |
Award Date | 04/03/2020 |
Closeout Date | 06/06/2024 |
Work Description | PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/05/2020) |
Sample Information
Sample Taken Date | 05/22/2023 | Sample Unique Key | 69 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1/2" RHMA-G 326120 SVA3 LTR |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shahjahan |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 23-151 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 016795 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 326120 SVA3 LTR |
Test Details
DIME Sample ID: 2023-05-22-69
DIME Test ID: 2023-05-22-69-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-06-05
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 05/30/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7359.3 grams
Mass of oven-dry sample in air for Sample 1: 1573.2 grams
Mass of container filled with the sample and water for Sample 1: 8274.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.392
Theoretical maximum density at 25°C (77°F): 148.9 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2023 ✔