Summary for Test 2023-05-19-33-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215396 DEA: 042K8404 EFIS: 0417000031 |
---|---|
DIST-CO-RTE-PM | 04-SOL-29,80-0.0,0.8/1.6 |
Award Date | 03/26/2021 |
Closeout Date | 02/16/2024 |
Work Description | HMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR. |
Location Description | SOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/25/2021) |
Sample Information
Sample Taken Date | 05/19/2023 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA Type A |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Bradley | Last name of sampler or witnessed by | Fitch |
Title of sampler | QC Technician | Telephone number of sampler | 7076747404 |
Laboratory sample identification | Con_23_519 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Vallejo | Transportation Laboratory (TL) Number | C726351 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 1 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 411101510LD |
Test Details
DIME Sample ID: 2023-05-19-33
DIME Test ID: 2023-05-19-33-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-05-26
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Nick Hall
Date of test: 05/26/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3155.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 5454.8 g
Mass of HMA Sample prior to ignition: 2299.5 g
Mass Loss: 160.9 g
Mass of aggregate remaining after ignition: 2138.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.58 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.09 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.33 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/26/2023 ✔