Summary for Test 2016-12-13-2-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 209141 DEA: 07215954 EFIS: 0700001835 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-0.0/7.6 |
Award Date | 04/24/2014 |
Closeout Date | 07/14/2022 |
Work Description | WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES |
Location Description | LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605 |
QA Service Level | 1 (Verified on 06/02/2014) |
Sample Information
Sample Taken Date | 12/13/2016 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/15/2016 |
Sample type | Acceptance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Rick | Last name of sampler or witnessed by | Bettencourt |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Confab Sumiden Wire | Transportation Laboratory (TL) Number | C719042 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S2510316 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S333924, S377688-1 | Number of Coils | 2 |
Group Number | Unknown | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0288054, S0534716 | Mfg. Lot Number(s) | SIPC163173, SIPC162848 |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2016-12-13-2
DIME Test ID: 2016-12-13-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-12-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 12/16/2016
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0288054 | S333924 | 0.214 | 60129 | 54839 | 28.6 | 1.73 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 12/19/2016 ✔