Summary for Test 2016-11-18-7-3
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211411 DEA: 072849U4 EFIS: 0715000267 |
---|---|
DIST-CO-RTE-PM | 07-LA-118-R4.8 |
Award Date | 06/27/2016 |
Closeout Date | 09/10/2018 |
Work Description | WIDEN WESTBOUND OFF RAMP TO INCREASE STORAGE |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT TAMPA AVENUE OFF-RAMP |
QA Service Level | 1 (Verified on 06/06/2016) |
Sample Information
Sample Taken Date | 11/18/2016 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/23/2016 |
Sample type | Quality Assurance | A brief description of the sample | CONCRETE CYLINDERS |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | A | Last name of sampler or witnessed by | PIMIENTA |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | ROBERTSONS | Transportation Laboratory (TL) Number | 161118 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | S590B38 |
---|---|---|---|
The truck number from where the sample was collected | 1708 | The batch plant ticket number from where the sample was collected | 2551794 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | RW 9 FOOTING 7 TO 19 | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-11-18-7
DIME Test ID: 2016-11-18-7-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-12-23
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/16/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 126420 lb
Maximum load on cylinder 2: 124900 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4442.0 psi
Compressive strength of cylinder 2: 4388.6 psi
Compressive strength (to nearest 10 psi): 4420 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2016 ✔