Summary for Test 2023-02-10-50-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 215486 DEA: 040A0204 EFIS: 0400000129 |
---|---|
DIST-CO-RTE-PM | 04-SON-1-15-15.7 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Construct roadway and bridge with structural concrete and CIDH piling |
Location Description | District-County-Route-Post Mile: 04-Son-1-R15.0/R15.7 |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 02/10/2023 | Sample Unique Key | 50 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/10/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Cody | Last name of sampler or witnessed by | Brown |
Title of sampler | Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bodean - Santa Rosa | Transportation Laboratory (TL) Number | 101340 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | D04 JMF 22 011 |
Test Details
DIME Sample ID: 2023-02-10-50
DIME Test ID: 2023-02-10-50-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-03-03
Test Results
Number of tests: 2
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Glenn Cea
Date of test: 02/14/2023
Method Performed: no data
Mass of container filled with water: 7389.4 grams
Mass of oven-dry sample in air for Sample 1: 2543.2 grams
Mass of container filled with the sample and water for Sample 1: 8953.4 grams
Mass of container filled with water: 7389.4 grams
Mass of oven-dry sample in air for Sample 2: 2538.2 grams
Mass of container filled with the sample and water for Sample 2: 8949.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.597
Specific Gravity for Sample 2: 2.596
Average Specific Gravity: 2.596
Theoretical maximum density at 25°C (77°F): 161.6 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Theoretical Maximum Density =2.589
Test was verified on 3/3/2023 ✔