Summary for Test 2023-02-13-21-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 993482 DEA: 060V2804 EFIS: 0616000124 |
---|---|
DIST-CO-RTE-PM | 06-KER-184-L0.9/L1.1 |
Award Date | 02/24/2022 |
Closeout Date | 02/26/2024 |
Work Description | PLACE HMA AND MINOR CONCRETE, REPLACE ELECTRICAL & LIGHTING SYSTEMS. |
Location Description | KERN COUNTY NEAR LAMONT FROM 0.1 MILE SOUTH TO 0.1 MILE NORTH OF SUNSET BOULEVARD |
QA Service Level | 1 (Verified on 01/03/2022) |
Sample Information
Sample Taken Date | 02/13/2023 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/13/2023 |
Sample type | Department Acceptance | A brief description of the sample | Native Soil- Mostly Sitty few sand, |
The quantity of what the sample constitutes | 30 lBS | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
Title of sampler | Tester | Telephone number of sampler | 6615498281 |
Laboratory sample identification | 21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Sta 15+09.82 to 21+25.77 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Test holes at jobsite | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-02-13-21
DIME Test ID: 2023-02-13-21-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-02-13
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 02/13/2023
Gage No.: 30699
Test No.: 21
Nuclear By: Neale Brown
Non-Bias Plan No.: 4- even
Depth: 8
Material No.: no data
Material Type: mostly silt and few sand
Impact By: Neale Brown
Standard Count Density: 1939 g/cc
Count or Density 1: 1459 g/cc
Count or Density 2: 1307 g/cc
Count or Density 3: 1303 g/cc
Standard Count Moisture: 629 g/cc
Moisture Count 1: 61 g/cc
Moisture Count 2: 65 g/cc
Moisture Count 3: 105 g/cc
Sum of Count or Density: 4069.00 g/cc
Average of Count or Density: 1356.00 g/cc
Sum of Moisture Count: 231.00 g/cc
Average of Moisture Count: 77.00 g/cc
Count Ratio Density: 0.70
Count Ratio Moisture: 0.12
Calculated Percent Relative Compaction: 94.7 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters): NE corner curb and gutter sta 15+09.82 and 21+25.77 Elevation: FG width 2' 8" probe
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-0V2804_37016_230213_19to22 | 546.82 KB | 02/13/2023 | 2023-02-13-21-1 | Info |
Test was verified on 2/13/2023 ✔