Summary for Test 2022-11-09-36-5

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date11/09/2022 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/10/2022
Sample typeVerification A brief description of the sampleA set of 2 CRCP concrete beam test specimens
The quantity of what the sample constitutesDaily Production From where was the sample collectedJob Site
First name of sampler or witnessed byJacob Last name of sampler or witnessed byGregory
Title of sampler Telephone number of sampler
Laboratory sample identification657 Linked DIME Sample ID
The fabricator/manufacturer/facility nameElite Ready Mix Bradshaw Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCT600
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampledroadway
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-11-09-36
DIME Test ID: 2022-11-09-36-5
Testing Lab: CT D03 - Rocklin Construction Field Office
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-02-08

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Ernesto Sanchez
Date of test: 12/07/2022
Identification number: 8-1
Width of specimen: 6.00 inch
Width of specimen 2: 6.05 inch
Width of specimen 3: 6.10 inch
Depth of specimen: 6.05 inch
Depth of specimen 2: 6.05 inch
Depth of specimen 3: 6.05 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7480 lb
Maximum load applied 2: 7500 lb
Maximum load applied 3: 7570 lb
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen: 0
Age of specimen: 27 days
Age of specimen in hours: no data
Modulus of rupture: 615 psi
Modulus of rupture 2: 610 psi
Modulus of rupture 3: 610 psi
Modulus of rupture average: 610 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
3758.x 0H08U4 28 Day Beam Flextural Strength Report cast on 11-9-22pdf108.17 KB02/08/20232022-11-09-36-5   Info

Test was verified on 2/8/2023