Summary for Test 2022-11-23-14-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993805
DEA: 070W1404
EFIS: 0721000062
DIST-CO-RTE-PM07-VEN-1-4.4/9.7
Award Date06/24/2022
Closeout Date03/13/2025
Work DescriptionCOLD PLACE AC PAVEMENT AND PLACE RHMA-G.
Location DescriptionVENTURA COUNTY FROM BIG SYCAMORE MAINTENANCE STATION AND PARK TO 0.2 MILE SOUTH OF GALLEGUAS GREEK BRIDGE
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date11/23/2022 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/29/2022
Sample typeVerification A brief description of the sample1/2" RHMA-G-SP 0.5% WMA
The quantity of what the sample constitutes4 Bags of Combined Aggregate From where was the sample collectedJob Site
First name of sampler or witnessed byVulcan QC Last name of sampler or witnessed byVulcan QC
Title of sampler Telephone number of sampler
Laboratory sample identification0760G-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Saticoy Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0020
The fabricator's/manufacturer's product name for the sampleVulcan Materials Saticoy The fabricator/manufacturer designation for the sampleVulcan Materials Saticoy
The plant number A detailed description of where the material sample was collectedBeltcut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number326122 SAT VLO Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2022-11-23-14
DIME Test ID: 2022-11-23-14-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-01-25

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 11/03/2022
Mass of saturated surface dry sample (before pycnometer) (S): 500.0 grams
Mass of the pycnometer with water and aggregate (C): 985.6 grams
Mass of the pycnometer with water (B): 674.7 grams
Mass of the oven dried sample (before pycnometer) (A): 492.1 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.0 grams
Mass of the oven dry aggregate (for absorption) (A): 492.1 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.602
Bulk specific gravity (SSD Basis): 2.644
Apparent specific gravity: 2.716
Absorption: 1.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/25/2023