Summary for Test 2022-10-27-29-6

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date10/27/2022 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/28/2022
Sample typeAcceptance A brief description of the sample1x4 PCC Aggregates
The quantity of what the sample constitutes400 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFCI PCC Portable Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0023
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sampleMix JPCP-3215-06
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberJPCP-3215-06 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2022-10-27-29
DIME Test ID: 2022-10-27-29-6
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-11-14

Test Results


Number of tests: 2
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 10/28/2022
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5
Sand reading (test 1): 4.4
Clay reading (test 2): 4.9
Sand reading (test 2): 4.1
Sand equivalent (test 1): 88
Sand equivalent (test 2): 84
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/14/2022