Summary for Test 2022-10-25-11-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date10/25/2022 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2022
Sample typeDepartment Acceptance A brief description of the sample204 SF
The quantity of what the sample constitutesStructural Backfill From where was the sample collectedJob Site
First name of sampler or witnessed byMichelangelo Last name of sampler or witnessed bySese
Title of samplerTET Telephone number of sampler310-345-6204
Laboratory sample identification22-2868 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleStructure Backfill
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedVarious locations
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-10-25-11
DIME Test ID: 2022-10-25-11-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-10-26

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 10/25/2022
Gage No.: 60203
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: 6
Depth: 12
Material No.: no data
Material Type: Structure Backfill
Impact By: Michelangelo Sese
Standard Count Density: 2340 g/cc
Count or Density 1: 2.14 g/cc
Count or Density 2: 2.19 g/cc
Count or Density 3: 2.22 g/cc
Standard Count Moisture: 645 g/cc
Moisture Count 1: 0.2 g/cc
Moisture Count 2: 0.24 g/cc
Moisture Count 3: 0.21 g/cc
Sum of Count or Density: 6.55 g/cc
Average of Count or Density: 2.18 g/cc
Sum of Moisture Count: 0.65 g/cc
Average of Moisture Count: 0.22 g/cc
Calculated Percent Relative Compaction: 92.1 %
Reported Percent Relative Compaction: 92 %
General comments (publicly viewable) (Max 1000 characters): Rte. 71 DS 11-7 RCB 11-7 West Side 1st Lift Sta. 171+88 to Sta. 172+90

Test was verified on 10/26/2022