Summary for Test 2016-08-29-18-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209950
DEA: 080N56U4
EFIS: 0813000176
DIST-CO-RTE-PM08-SBD-40-R94.7/R99.7
Award Date01/22/2015
Closeout Date09/17/2018
Work DescriptionBRIDGE REPLACEMENTS.
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
QA Service Level1 (Verified on 04/29/2015)

Sample Information

Sample Taken Date08/29/2016 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedManufacturer
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberC953736
Inspector Lot Number from the Transportation Laboratory (TL) FormL7511716 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65020527
Hoop Manufacturer Lot Number(s)1, 6 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-08-29-18
DIME Test ID: 2016-08-29-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-09-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/06/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#6/19mm0.444296097640Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 9/6/2016