Summary for Test 2016-07-27-4-1
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 211118 DEA: 021H0404 EFIS: 0215000099 |
---|---|
DIST-CO-RTE-PM | 02-LAS-299-12.2/18.5 |
Award Date | 03/15/2016 |
Closeout Date | 09/05/2018 |
Work Description | ASPHALT RUBBER SEAL COAT, PLACE HMA WITH REPLACE AC SURFACING |
Location Description | Not set |
QA Service Level | 1 (Verified on 09/22/2016) |
Sample Information
Sample Taken Date | 07/27/2016 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2016 |
Sample type | Verification | A brief description of the sample | 1/2 HMA Type A |
The quantity of what the sample constitutes | sample as recieved | From where was the sample collected | Source |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Ortiz |
Title of sampler | TET | Telephone number of sampler | Unknown |
Laboratory sample identification | 16FPCC-0319 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Hogsback | Transportation Laboratory (TL) Number | c847796 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-25-0029 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | untreated Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2016-07-27-4
DIME Test ID: 2016-07-27-4-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2016-09-06
Test Results
What size aggregate is being tested?: Fine and Coarse Aggregate
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 09/06/2016
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on #4 sieve: no data
Percentage Loss of material retained on #8 sieve: no data
Percentage Loss of material retained on #16 sieve: no data
Percentage Loss of material retained on #30 sieve: no data
Percentage Loss of material retained on #50 sieve: no data
Percentage Loss of material retained on #100 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 3.7 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
Weighted Average Percent Loss of Fine Aggregate: 1.6 %
General comments (publicly viewable) (Max 1000 characters): Test run per AASHTO T-104
Test was verified on 9/6/2016 ✔