Summary for Test 2016-08-29-14-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209918
DEA: 07274804
EFIS: 0700000516
DIST-CO-RTE-PM07-LA-18-0.2
Award Date12/09/2014
Closeout Date01/15/2018
Work DescriptionREPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location DescriptionLOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
QA Service Level1 (Verified on 01/08/2015)

Sample Information

Sample Taken Date08/29/2016 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2016
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed bySarah Last name of sampler or witnessed byHartz
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor ArcelorMittal BarSplice Transportation Laboratory (TL) NumberC409468 C866876
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor ArcelorMittal
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size4 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsASTM A775 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5155 Rebar Heat Number(s)1512769 PL1620040151
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-08-29-14
DIME Test ID: 2016-08-29-14-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-09-02

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/02/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1321#4/13mm0.21745187260Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 9/2/2016