Summary for Test 2022-04-29-45-4

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 214663
DEA: 081F7304
EFIS: 0815000034
DIST-CO-RTE-PM08-SBD-215-2.7
Award DateNot set
Closeout DateNot set
Work DescriptionREPLACE CONCRETE BRIDGE, PLACE CONCRETE PCPS GIRDERS AND HMA.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AT WASHINGTON STREET OVERCROSSING
QA Service Level1 (Verified on 02/24/2021)

Sample Information

Sample Taken Date04/29/2022 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2022
Sample typeQuality Control A brief description of the sampleRock and Sand
The quantity of what the sample constitutes1 Bag From where was the sample collectedJob Site
First name of sampler or witnessed byBobby Last name of sampler or witnessed byTogores
Title of samplerQC Field Technician Telephone number of samplerUnknown
Laboratory sample identificationMix 1611614 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number1611614 Lot number1
Sublot number1 Aggregate Mix NumberNot set

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
No assigned tests for this sample.

Test Details

DIME Sample ID: 2022-04-29-45
DIME Test ID: 2022-04-29-45-4
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2022-09-21

Test Results


Input Type: Calculated
Tester's full name: Bryce Trudeau
Date of test: 04/30/2022
Wet weight of the sample: 538.0000000000 grams
Dry weight of the sample: 498.5000000000 grams
Weight of water in sample: 39.5000000000 grams
Percent moisture: 7.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/21/2022