Summary for Test 2016-08-19-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211025
DEA: 11414904
EFIS: 1112000206
DIST-CO-RTE-PM11-SD-67-R21.0/21.6
Award Date02/24/2016
Closeout Date06/11/2021
Work DescriptionWIDEN INTERSECTION AND COLD PLANE AND OVERLAY WITH HMA.
Location DescriptionIN SAN DIEGO COUNTY NEAR RAMONA FROM 0.4 MILE SOUTH TO O.3 MILE NORTH OF HIGHLAND VALLEY ROAD/DYE ROAD.
QA Service Level1 (Verified on 04/19/2016)

Sample Information

Sample Taken Date08/19/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/22/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC740872
Inspector Lot Number from the Transportation Laboratory (TL) FormB1036116 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)586353
Hoop Manufacturer Lot Number(s)H01 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEVRAZ
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-08-19-1
DIME Test ID: 2016-08-19-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/24/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13H01#5/16mm0.312976096000Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/25/2016