Summary for Test 2022-07-06-66-1
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/06/2022 | Sample Unique Key | 66 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2022 |
Sample type | Verification | A brief description of the sample | Tank 38 |
The quantity of what the sample constitutes | 1 of 2 split sample | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Keven | Last name of sampler or witnessed by | Heitschmidt |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | PG64287622KF38 | Linked DIME Sample ID | 2022-07-06-60 |
The fabricator/manufacturer/facility name | Klamath Falls, OR | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 38 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt - Klamath Falls Plant - Klamath Falls OR | Multigrade | Yes |
Multigrade Type | PG 64-28 / PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-06-66
DIME Test ID: 2022-07-06-66-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-26
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Adam Herrera
Date of test: 08/25/2022
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.199 kPa
Phase Angle (δ) (for the 10 cycles): 81.2 degree
Complex Modulus (G*) (for the 10 measurements): 1.658 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.68 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 8/26/2022 ✔