Summary for Test 2016-07-21-17-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/21/2016 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/28/2016 |
Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jim | Last name of sampler or witnessed by | Hoenig |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Insteel Stressteel | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | Unknown | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | 16103422 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Insteel Stressteel |
Test Details
DIME Sample ID: 2016-07-21-17
DIME Test ID: 2016-07-21-17-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-08-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/04/2016
UTM: 120KIP
Temperature: 74 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 16103422 | 1302466153331 | 0.218 | 60919 | 55297 | 28.3 | 1.7 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/5/2016 ✔