Summary for Test 2016-07-25-11-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210959
DEA: 08465524
EFIS: 0815000118
MINOR: 08A2540
DIST-CO-RTE-PM08-RIV-74-16.1/71.8
Award Date08/06/2015
Closeout Date08/10/2018
Work DescriptionCONSTRUCTION ON STATEƃ ? HIGHWAY IN VARIOUS CITIES, ROUTES AND POST MILES IN RIVERSIDE COUNTY.
Location DescriptionVarious locations in Riverside County
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date07/25/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRussel Last name of sampler or witnessed byLynch
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC952650
Inspector Lot Number from the Transportation Laboratory (TL) FormL9607416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL1410777
Hoop Manufacturer Lot Number(s)1, 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-07-25-11
DIME Test ID: 2016-07-25-11-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/29/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
122#4/13mm0.220440102200Bar Broke in Heat Affected AreaFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/1/2016