Summary for Test 2022-07-13-64-5

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215374
DEA: 060X2704
EFIS: 0618000048
DIST-CO-RTE-PM06-FRE-5-37.2/48.8
Award DateNot set
Closeout DateNot set
Work DescriptionPAVEMENT REHABILITATION
Location DescriptionFROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
QA Service Level1 (Verified on 12/16/2020)

Sample Information

Sample Taken Date07/13/2022 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/21/2022
Sample typeAcceptance A brief description of the samplePG70-10
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byG Litt Last name of sampler or witnessed byNA
Title of samplerNA Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number039496
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-13-64
DIME Test ID: 2022-07-13-64-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-01

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/28/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 44.563 kPa
Phase Angle (δ) (for the 10 cycles): 61.2 degree
Complex Modulus (G*) (for the 10 measurements): 4456.361 kPa
Test Temperature (Specimen 1): 37.0 C
(G*) x sin(δ)=: 3905 kPa
General comments (publicly viewable) (Max 1000 characters): pav+3

Test was verified on 8/1/2022